Red Hat CLUSTER SUITE FOR ENTERPRISE LINUX 4.5 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Servidores Red Hat CLUSTER SUITE FOR ENTERPRISE LINUX 4.5. Dell HPC NFS Storage Solution High Availability Configurations with Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 80
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Xin Chen, Garima Kochhar
and Mario Gallegos
Dell HPC Engineering
Version 2.1, May 2012
Dell HPC NFS Storage Solution
High Availability Configurations
with Large Capacities
High availability NSS configurations for capacities greater than 100TB.
Vista de página 0
1 2 3 4 5 6 ... 79 80

Resumo do Conteúdo

Página 1 - Version 2.1, May 2012

Xin Chen, Garima Kochhar and Mario Gallegos Dell HPC Engineering Version 2.1, May 2012 Dell HPC NFS Storage Solution High Availability

Página 2

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 10 Appendix A: NSS-HA Recipe includes detailed instructions on t

Página 3 - Contents

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 11 NFS server configuration in NSS-HA Figure 4. The NSS-HA arc

Página 4

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 12 2) Step 2 – Logical volume configuration In this step, a log

Página 5 - Figures

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 13 3.2. Potential failures and fault tolerant mechanisms in NSS

Página 6

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 14 New components and updates from previous versions of the 4.s

Página 7 - NSS-HA solution review

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 15 4.2. Storage configuration In previous versions of the solut

Página 8

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 16 release, do not refer to the instructions listed in the previ

Página 9 - 2.1. Availability in NSS-HA

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 17 New server components in this release Table 4.Server compon

Página 10 - NSS-HA architecture 3

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 18 5.4 describes these functionality tests and their results. Fu

Página 11 - 3.1. Storage in NSS-HA

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 19 NSS-HA test bed Figure 7.

Página 12 - Figure 5

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities ii This document is for informational purpose

Página 13 - Table 1

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 20 NSS-HA hardware configuration details Table 5.

Página 14 - 4.1. Storage density

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 21 NSS-HA software configuration details Table 6.SOFTWARE Oper

Página 15 - 4.2. Storage configuration

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 22 NSS-HA client configuration details Table 8.Client / HPC Co

Página 16 - 4.5. Summary of changes

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 23 NFS Server configuration 7) The XFS file system is mounted w

Página 17 - Evaluation 5

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 24 2) Heartbeat link failure - simulated by disconnecting the p

Página 18 - 5.2. Test bed

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 25 Impact to clients Clients mount the NFS file system exported

Página 19 - NSS-HA test bed Figure 7

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 26 Metadata tests were performed using the mdtest benchmark and

Página 20

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 27 The sequential read performance as shown in Figure 9 peaks at

Página 21

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 28 10GbE large sequential write performance Figure 10. 10G

Página 22 - 5.3. Tuning options

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 29 A single NFS client with a 10 Gigabit Ethernet to the storage

Página 23 - 5.4. Functionality tests

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities iii Contents Executive summary (Updated May 2012) ...

Página 24

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 30 InfiniBand random write performance Figure 13. The NSS-HA

Página 25 - Performance tests 6

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 31 InfiniBand random read performance Figure 14. 6.4. Metada

Página 26 - Throughput in MB/s

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 32 expected the file create and file remove performance is simil

Página 27

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 33 InfiniBand file stat performance Figure 16. InfiniBand f

Página 28 - Throughput: MB/sec

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 34 6.5. NFSv3 compared to NFSv4 During the design and analysis

Página 29

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 35 With IPoIB, sequential reads were found to be up to 22% bette

Página 30 - IB Random Write Performance

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 36 operations, NFSv3 versus NFsv4 performance depended on the nu

Página 31 - IB Random Read Performance

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 37 References 8.1) XFS: A high-performance journaling file sys

Página 32 - IB File Create Performance

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 38 Appendix A: NSS-HA Recipe (Updated May 2012) Contents A.1. P

Página 33 - IB File Remove Performance

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 39 A.1. Pre-install preparation The following figure shows an N

Página 34

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities iv A.3.2. Configure Multipath...

Página 35

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 40 A.1.1. NSS-HA cluster specification The section gives a detai

Página 36 - Conclusion 7

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 41 PDU 2 Login name: apc password: apc port 2 for active, por

Página 37 - References 8

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 42 nssha61_single.py Configuring storage devices, including crea

Página 38

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 43 A.2. Server hardware setup 1. Prepare two PowerEdge R710 ser

Página 39

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 44 A.2.1. Checklist Before moving to the next section, please ma

Página 40

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 45 A.3. Server software configuration All the operations below

Página 41

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 46 A.3.2. Configure Multipath On each R710, exclude the local di

Página 42 - A.1.2. Checklist

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 47 Then, edit the file /etc/multipath.conf, search for the black

Página 43 - A.2. Server hardware setup

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 48 A.3.3. Install Mellanox OFED package and set network IPs 1.

Página 44 - A.2.1. Checklist

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 49 A.3.4. Install Operating system and storage management tools

Página 45 - -3.0.4-2.el6.x86_64.rpm

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities v Figures Figure 1. Overview of the NSS-HA solution ...

Página 46 - A.3.2. Configure Multipath

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 50 A.3.5. Network security setting In this step ports will be en

Página 47

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 51 LOCKD_TCPPORT=890 LOCKD_UDPPORT=890 MOUNTD_PORT=892 STATD_POR

Página 48

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 52 2. Configure two APC PDUs, and make sure the login name, pas

Página 49

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 53 A.3.8. Checklist Before moving to the next section, please ma

Página 50

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 54 A.4. Performance tuning on the server All the operations bel

Página 51

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 55 Restart the NFS service, service nfs restart Run the nfsstat

Página 52

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 56 A.5. Storage hardware setup 1. Cable the MD3200 to the SAS 6

Página 53 - A.3.8. Checklist

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 57  Cabling for 288TB configuration SAS INEMM 1EMM 2SAS OUTSAS

Página 54

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 58 Note: Do not cable storage to R710 before OS install, and us

Página 55 - A.4.1. Checklist

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 59 A.6. Storage configuration 1. Launch the MDSM management GU

Página 56 - A.5. Storage hardware setup

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 6 Executive summary (Updated May 2012) This solution guide descr

Página 57 - Port 0 Port 1 Port 0 Port 1

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 60 Make sure the host port identifiers on each R710 match the sa

Página 58

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 61 A.6.1. Checklist Before moving to the next section, please ma

Página 59 - A.6. Storage configuration

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 62 A.7. NSS HA cluster setup In this recipe the term “cluster”

Página 60

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 63 6. Check that the public interface is up on both servers. Th

Página 61 - A.6.1. Checklist

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 64 1. Generate cluster configuration file. On the „active‟ R710

Página 62 - A.7. NSS HA cluster setup

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 65 ------ ---- ---- ------ active

Página 63 - A.7.2. Create HA cluster

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 66 [root@active ~]# clustat Cluster Status for NSS61 @ Thu Jan

Página 64

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 67 An SELinux policy can be generated from logs of denied operat

Página 65 - A.7.3. Verification

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 68 A.8. Quick test of HA setup 1. Test fencing: o First disabl

Página 66

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 69 A.9. Useful commands and references This section provides sev

Página 67

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 7 Introduction 1.This Solution Guide provides information on

Página 68 - A.8. Quick test of HA setup

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 70 3. Start cluster service. Assume the service name is HA1, it

Página 69

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 71 # service cman stop A.9.5. Configure the shared storage array

Página 70

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 72 size=27T features='3 queue_if_no_path pg_init_retries 50

Página 71

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 73 a. Configure 144TB storage array. # vgcreate VGMD1 /dev/mapp

Página 72

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 74 A.10. Performance tuning on clients 1. If the clients acce

Página 73

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 75 A.11. Scripts 1. /root/config_cluster.sh file for automati

Página 74

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 76 Appendix B: Benchmarks and test tools The iozone benchmark wa

Página 75 - A.11. Scripts

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 77 The following table describes the IOZone command line argumen

Página 76 - B.1. IOzone

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 78 IOzone IOPs Random Access (Reads and Writes) # /usr/sbin/ioz

Página 77

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 79 As with the IOzone random access patterns, the following proc

Página 78 - B.2. mdtest

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 8 Overview of the NSS-HA solution Figure 1.

Página 79 - B.3. Checkstream

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 80 For comparison, here is an example of a failing test with dat

Página 80 - B.4. dd

Dell HPC NFS Storage Solution High Availability Configurations with Large Capacities 9 2.1. Availability in NSS-HA A major goal of the NSS-HA soluti

Comentários a estes Manuais

Sem comentários