Red Hat Server tc3100 Guia do Utilizador Página 99

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 98
Troubleshooting 99
Troubleshooting
Figure 50. Sample Hardware Event Notification
Notification Time: Wed Feb 3 11:27:15 1999
yourserver sent Event Monitor notification information:
/storage/events/enclosures/ses_enclosure/8_0_1_0.15.0 is >=1.
Its current value is MAJORWARNING(3)
Event data from monitor:
Event Time: Wed Feb 3 11:27:15 1999
Hostname: yourserver.rose.hp.com IP Address : 15.43.213.13
Event ID: 0x0036b8a313000000002 Monitor : dm_ses_enclosure
Event # : 402 Event Class: I/O
Severity : MAJOR WARNING
Enclosure at hardware path 8/0/1/0.15.0: Hardware failure
Associated OS error log entry id(s): None
Description of Error:
The enclosure services controllers have different versions of
firmware.
Probable Cause / Recommended Action:
The enclosure services controller cards have different versions
of firmware. Update the controllers to the same version of
firmware.
User Defined Annotation: Enclosure 37 BCC A.